CIRCUIT BREAKER
Price to win
From deduped DIBBS award lines (unit cost × quantity). Not a bid recommendation — observed history only.
Average unit cost
$1,947.00
Weighted average
$196.31
Weighted by quantity
Observed range
$68.99–$3,825
Coverage
2 awards
Nov 30, 1987 – Aug 17, 2026
Average: $1,947.00 · Weighted avg: $196.31 · Range: $68.99–$3,825.00 · Based on 2 awards, Nov 30, 1987–Aug 17, 2026.
Trend chart needs at least 4 priced awards in this window (2 available).
DIBBS award history
Distinct award lines for this NSN (deduped). Line total is unit cost × quantity.
2 distinct award lines
Manufacturers who have won this NSN
Distinct CAGEs with a confirmed DIBBS award line for this part — each opens the manufacturer page.
Approved manufacturers
Qualified to supply per MCRL — no confirmed DIBBS award on record for this NSN. Each CAGE opens the manufacturer page.
PN 2892361-3
PN 3664017
PN 2892361-3
PN 2601D45G03
PN 565B159G15
Characteristics
FLIS item characteristics from PUB LOG identification.
| Characteristic | Value |
|---|---|
| ACTUATOR FUNCTION | TRIP-RESET |
| ACTUATOR POSITION DESIGNATION | AT POLE ONE |
| AUXILIARY SWITCH FUNCTION AND QUANTITY | ALARM 1 |
| BODY HEIGHT | INCHES MINIMUM 3.040 AND INCHES MAXIMUM 3.080 |
| BODY LENGTH | INCHES MINIMUM 3.480 AND INCHES MAXIMUM 3.520 |
| BODY WIDTH | INCHES MINIMUM 0.940 AND INCHES MAXIMUM 0.980 |
| BOSS HEIGHT | INCHES MINIMUM 0.178 AND INCHES MAXIMUM 0.198 |
| CIRCUIT PROTECTION TYPE | SINGLE LOCATION OVERCURRENT |
| FREQUENCY IN HERTZ | 400.0 |
| MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| MANUAL ACTUATOR TYPE AND QUANTITY | TOGGLE 1 |
| MATERIAL | CASE PLASTIC |
| MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | SINGLE LOCATION AMPERES AC 15.0 AND AMPERES DC 15.0 |
| MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | SINGLE LOCATION AC 5000.0 AND DC 2500.0 |
| MOUNTING FACILITY TYPE AND QUANTITY | TERMINAL 1 |
| OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | SINGLE LOCATION AC 300.0 AND DC 125.0 |
| POLE QUANTITY | 1 |
| RESET METHOD | MANUAL |
| SWITCH CONTACT ARRANGEMENT | SINGLE POLE, DOUBLE THROW |
| SWITCH CURRENT RATING AND TYPE IN AMPS | AC 5.0 AND DC 5.0 |
| SWITCH LOCATION AND POSITION DESIGNATION | EXTERNAL AT POLE ONE |
| SWITCH TERMINAL TYPE | TURRET |
| SWITCH VOLTAGE RATING AND TYPE IN VOLTS | AC 250.0 AND DC 30.0 |
| TERMINAL TYPE AND QUANTITY | SOLDER STUD 1 AND TAB W/SCREW 1 |
| TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | SINGLE LOCATION MINIMUM AT 200 PCT 10.000 AND MAXIMUM AT 200 PCT 210.000 |
| TRIP RELEASE AMBIENT TEMP RATING | SINGLE LOCATION CELSIUS NOMINAL 50.0 |
| TRIP RELEASE CHARACTERISTIC | SINGLE LOCATION INSTANTANEOUS AND TIME DELAY |
| TRIP RELEASE METHOD | SINGLE LOCATION THERMAL-MAGNETIC |
| ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 150.0 |